Circuit Breaking In Spring Cloud Gateway With Resilience4J
source link: https://piotrminkowski.wordpress.com/2019/12/11/circuit-breaking-in-spring-cloud-gateway-with-resilience4j/
Go to the source link to view the article. You can view the picture content, updated content and better typesetting reading experience. If the link is broken, please click the button below to view the snapshot at that time.

Circuit Breaking In Spring Cloud Gateway With Resilience4J
In the newest version of Spring Cloud Gateway (2.2.1
) we may take an advantage of a new implementation of circuit breaker built on top of project Resilience4J (https://github.com/resilience4j/resilience4j). Resilience4J has been selected as a replacement for Netflix’s Hystrix, that had been moved to the maintenance mode. Of course, you can still use Hystrix as circuit breaker implementation, however it is deprecated and probably won’t be available in the future versions of Spring Cloud. A new implementation is called no different than just Spring Cloud Circuit Breaker.
You can find another interesting example of using Spring Cloud Gateway components in one of previous articles. I have already described how to implement rate limiting based on Redis here: Rate Limiting In Spring Cloud Gateway With Redis. In the current article I’m using the same GitHub repository as earlier: sample-spring-cloud-gateway. I’m going to show some sample scenarios of using Spring Cloud Circuit Breaker with Spring Cloud Gateway including fallback pattern.
1. Dependencies
To succesfully test some scenarios of using a circuit breaker pattern with Spring Cloud Gateway we need to include reactive version of Spring Cloud Circuit Breaker since gateway is started on reactive Netty server. We will simulate downstream service using MockServer provided within Testcontainers framework. It is provisioned inside the test by mock client written in Java.
<
dependency
>
<
groupId
>org.springframework.cloud</
groupId
>
<
artifactId
>spring-cloud-starter-gateway</
artifactId
>
</
dependency
>
<
dependency
>
<
groupId
>org.springframework.boot</
groupId
>
<
artifactId
>spring-cloud-starter-circuitbreaker-reactor-resilience4j</
artifactId
>
</
dependency
>
<
dependency
>
<
groupId
>org.projectlombok</
groupId
>
<
artifactId
>lombok</
artifactId
>
</
dependency
>
<
dependency
>
<
groupId
>org.springframework.boot</
groupId
>
<
artifactId
>spring-boot-starter-test</
artifactId
>
<
scope
>test</
scope
>
</
dependency
>
<
dependency
>
<
groupId
>org.testcontainers</
groupId
>
<
artifactId
>mockserver</
artifactId
>
<
version
>1.12.3</
version
>
<
scope
>test</
scope
>
</
dependency
>
<
dependency
>
<
groupId
>org.mock-server</
groupId
>
<
artifactId
>mockserver-client-java</
artifactId
>
<
version
>3.10.8</
version
>
<
scope
>test</
scope
>
</
dependency
>
<
dependency
>
<
groupId
>com.carrotsearch</
groupId
>
<
artifactId
>junit-benchmarks</
artifactId
>
<
version
>0.7.2</
version
>
<
scope
>test</
scope
>
</
dependency
>
2. Enabling Resilience4J Circuit Breaker
To enable circuit breaker built on top of Resilience4J we need to declare Customizer
bean that is passed a ReactiveResilience4JCircuitBreakerFactory
. The very simple configuration contains default circuit breaker settings and and defines timeout duration using TimeLimiterConfig
. For the first test I decided to set 200 milliseconds timeout.
@Bean
public
Customizer<ReactiveResilience4JCircuitBreakerFactory> defaultCustomizer() {
return
factory -> factory.configureDefault(id ->
new
Resilience4JConfigBuilder(id)
.circuitBreakerConfig(CircuitBreakerConfig.ofDefaults())
.timeLimiterConfig(TimeLimiterConfig.custom().timeoutDuration(Duration.ofMillis(
200
)).build())
.build());
}
3. Building Test Class
In the next step we are creating a test class. Before running the test it is starting and provisioning an instance of mock server. We are defining two endpoints. The second of them /2
adds a delay of 200 milliseconds, which exceeding timeout defined in the circuit breaker configuration.
We are also setting configuration of Spring Cloud Gateway route which is addressed to the currently started instance of mock server. To enable circuit breaker for our route we have to define CircuitBreaker
filter with a given name. The test is repeated 200 times. It calls delayed and not delayed endpoint in 50/50 proportion. Here’s the Spring Cloud Gateway test class.
@SpringBootTest
(webEnvironment = SpringBootTest.WebEnvironment.DEFINED_PORT)
@RunWith
(SpringRunner.
class
)
public
class
GatewayCircuitBreakerTest {
private
static
final
Logger LOGGER = LoggerFactory.getLogger(GatewayRateLimiterTest.
class
);
@Rule
public
TestRule benchmarkRun =
new
BenchmarkRule();
@ClassRule
public
static
MockServerContainer mockServer =
new
MockServerContainer();
@Autowired
TestRestTemplate template;
int
i =
0
;
@BeforeClass
public
static
void
init() {
System.setProperty(
"spring.cloud.gateway.routes[0].id"
,
"account-service"
);
System.setProperty(
"spring.cloud.gateway.routes[0].uri"
,
"http://192.168.99.100:"
+ mockServer.getServerPort());
System.setProperty(
"spring.cloud.gateway.routes[0].predicates[0]"
,
"Path=/account/**"
);
System.setProperty(
"spring.cloud.gateway.routes[0].filters[0]"
,
"RewritePath=/account/(?.*), /$\\{path}"
);
System.setProperty(
"spring.cloud.gateway.routes[0].filters[1].name"
,
"CircuitBreaker"
);
System.setProperty(
"spring.cloud.gateway.routes[0].filters[1].args.name"
,
"exampleSlowCircuitBreaker"
);
MockServerClient client =
new
MockServerClient(mockServer.getContainerIpAddress(), mockServer.getServerPort());
client.when(HttpRequest.request()
.withPath(
"/1"
))
.respond(response()
.withBody(
"{\"id\":1,\"number\":\"1234567890\"}"
)
.withHeader(
"Content-Type"
,
"application/json"
));
client.when(HttpRequest.request()
.withPath(
"/2"
))
.respond(response()
.withBody(
"{\"id\":2,\"number\":\"1234567891\"}"
)
.withDelay(TimeUnit.MILLISECONDS,
200
)
.withHeader(
"Content-Type"
,
"application/json"
));
}
@Test
@BenchmarkOptions
(warmupRounds =
0
, concurrency =
1
, benchmarkRounds =
200
)
public
void
testAccountService() {
int
gen =
1
+ (i++ %
2
);
ResponseEntity r = template.exchange(
"/account/{id}"
, HttpMethod.GET,
null
, Account.
class
, gen);
LOGGER.info(
"{}. Received: status->{}, payload->{}, call->{}"
, i, r.getStatusCodeValue(), r.getBody(), gen);
}
}
Here’s the result of currently discussed test. With default settings it opens circuit after processing 100 requests with 50% error rate. The logs visible below includes a sequence number of request, HTTP response status code, response body and URL of called endpoint.

We may change the default settings a little. To do that we should define a custom CircuitBreakerConfig
. One of the properties we can customize is slidingWindowSize
. The property slidingWindowSize
defines how many outcome calls has to be recorded when a circuit breaker is closed. Assuming we have the same test endpoints what will happen if we change this value to 10
as shown below?
@Bean
public
Customizer<ReactiveResilience4JCircuitBreakerFactory> defaultCustomizer() {
return
factory -> factory.configureDefault(id ->
new
Resilience4JConfigBuilder(id)
.circuitBreakerConfig(CircuitBreakerConfig.custom()
.slidingWindowSize(
10
)
.build())
.timeLimiterConfig(TimeLimiterConfig.custom().timeoutDuration(Duration.ofMillis(
200
)).build()).build());
}
Here’s the result. The circuit is open just after processing 10 requests when at least 50% of them is timeouted.

Moreover, we may change failureRateThreshold
. This property is responsible for configuring the failure rate threshold in percentage. If the failure rate is equal or greater than the threshold the circuit breaker is switched to open and starts short-circuiting calls. It is not difficult to predict what happen if we change it for our current scenario to 66.6F
. The circuit will never be opened.
@Bean
public
Customizer<ReactiveResilience4JCircuitBreakerFactory> defaultCustomizer() {
return
factory -> factory.configureDefault(id ->
new
Resilience4JConfigBuilder(id)
.circuitBreakerConfig(CircuitBreakerConfig.custom()
.slidingWindowSize(
10
)
.failureRateThreshold(
66
.6F)
.build())
.timeLimiterConfig(TimeLimiterConfig.custom().timeoutDuration(Duration.ofMillis(
200
)).build()).build());
}
4. Circuit Breaker Customization
We were starting with really basic samples. Let’s do something more interesting! First, we will set really small value of sliding window size. It set set to 5
. Thanks to that we will be able to observe the full result of the current test scenario after processing only a few requests. The next step is to modify a rules defined on the mock server. Now, we will delay only 5 first requests sent to the /2
endpoint. After receiving 5 requests it starts to works fine without adding any delay. Thanks to that fact our circuit breaker would be able to back from OPEN state to CLOSE after some time. But first things first, here are the code defining mock endpoints for the current test.
MockServerClient client =
new
MockServerClient(mockServer.getContainerIpAddress(), mockServer.getServerPort());
client.when(HttpRequest.request()
.withPath(
"/1"
))
.respond(response()
.withBody(
"{\"id\":1,\"number\":\"1234567890\"}"
)
.withHeader(
"Content-Type"
,
"application/json"
));
client.when(HttpRequest.request()
.withPath(
"/2"
), Times.exactly(
5
))
.respond(response()
.withBody(
"{\"id\":2,\"number\":\"1234567891\"}"
)
.withDelay(TimeUnit.MILLISECONDS,
200
)
.withHeader(
"Content-Type"
,
"application/json"
));
client.when(HttpRequest.request()
.withPath(
"/2"
))
.respond(response()
.withBody(
"{\"id\":2,\"number\":\"1234567891\"}"
)
.withHeader(
"Content-Type"
,
"application/json"
));
As I mentioned before the slidingWindowSize
is now equal to 5
. If there are 3 timeouts during last 5 calls the circuit is switched to OPEN state. We can configure how long the circuit should stay in the OPEN state without trying to process any request. The parameter waitDurationInOpenState
, which is responsible for that, has been set to 30 milliseconds. Therefore, after 30 milliseconds the circuit is switched to HALF_OPEN state, what means that the incoming requests are processing again. We can also configure a number of permitted calls in HALF_OPEN state. The property permittedNumberOfCallsInHalfOpenState
is set to 5
instead of default value 10
. In this five attempts we get only 2 timeouts, since we set 5 repeats for delayed service on the mock server and first 3 timeouts has been in the beginning before opening a circuit. Here’s our current configuration of Spring Cloud Circuit Breaker.
@Bean
public
Customizer<ReactiveResilience4JCircuitBreakerFactory> defaultCustomizer() {
return
factory -> factory.configureDefault(id ->
new
Resilience4JConfigBuilder(id)
.circuitBreakerConfig(CircuitBreakerConfig.custom()
.slidingWindowSize(
5
)
.permittedNumberOfCallsInHalfOpenState(
5
)
.failureRateThreshold(
50
.0F)
.waitDurationInOpenState(Duration.ofMillis(
30
))
.build())
.timeLimiterConfig(TimeLimiterConfig.custom().timeoutDuration(Duration.ofMillis(
200
)).build()).build());
}
The following diagram illustrates our scenario.

And here’s the result of our current test. The circuit has been opened after processing 6 requests. There was 3 incoming requests that has not been processed during 30 milliseconds of being in open state. After that time it has been switched to half open state and finally it moved back to close state.

What will happen if we increase the number of delayed requests in this scenario to 20?
client.when(HttpRequest.request()
.withPath(
"/2"
), Times.exactly(
20
))
.respond(response()
.withBody(
"{\"id\":2,\"number\":\"1234567891\"}"
)
.withDelay(TimeUnit.MILLISECONDS,
200
)
.withHeader(
"Content-Type"
,
"application/json"
));
The circuit will be switched between OPEN and HALF_OPEN state until the downstream service is delaying the responses.

5. Adding Fallback
As you probably noticed, if the request to the downstream service has been finished with timeout the gateway returned HTTP status HTTP 504 - Gateway Timeout
. Moreover, if a circuit is open the gateway is returning HTTP Status HTTP 503 - Service Unavailable
. To prevent from returning error status code on the gateway we may enable fallback endpoint for our route. To do that we have to set property fallbackUri
using forward:
scheme. Here’s the current configuration of the test route. I included the endpoint /fallback/account
as fallback URI.
System.setProperty(
"spring.cloud.gateway.routes[0].id"
,
"account-service"
);
System.setProperty(
"spring.cloud.gateway.routes[0].uri"
,
"http://192.168.99.100:"
+ mockServer.getServerPort());
System.setProperty(
"spring.cloud.gateway.routes[0].predicates[0]"
,
"Path=/account/**"
);
System.setProperty(
"spring.cloud.gateway.routes[0].filters[0]"
,
"RewritePath=/account/(?.*), /$\\{path}"
);
System.setProperty(
"spring.cloud.gateway.routes[0].filters[1].name"
,
"CircuitBreaker"
);
System.setProperty(
"spring.cloud.gateway.routes[0].filters[1].args.name"
,
"exampleSlowCircuitBreaker"
);
System.setProperty(
"spring.cloud.gateway.routes[0].filters[1].args.fallbackUri"
,
"forward:/fallback/account"
);
The fallback endpoint is exposed on the gateway. I defined simple controller class that implements single fallback method.
@RestController
@RequestMapping
(
"/fallback"
)
public
class
GatewayFallback {
@GetMapping
(
"/account"
)
public
Account getAccount() {
Account a =
new
Account();
a.setId(
2
);
a.setNumber(
"123456"
);
return
a;
}
}
Assuming we have exactly the same scenario as in the previous section the current test is returning only HTTP 200
instead of responses with HTTP 5xx
as shown below.

6. Handling Slow Responses
In the all previous examples we have set a short timeout on response, what results in HTTP 504 - Gateway Timeout
or fallback. However, we don’t have to timeout the requests, but we can just set a threshold and failure rate for indicating slow responses. There are two parameters responsible for that: slowCallDurationThreshold
and slowCallRateThreshold
.
@Bean
public
Customizer<ReactiveResilience4JCircuitBreakerFactory> defaultCustomizer() {
return
factory -> factory.configureDefault(id ->
new
Resilience4JConfigBuilder(id)
.circuitBreakerConfig(CircuitBreakerConfig.custom()
.slidingWindowSize(
5
)
.permittedNumberOfCallsInHalfOpenState(
5
)
.failureRateThreshold(
50
.0F)
.waitDurationInOpenState(Duration.ofMillis(
50
))
.slowCallDurationThreshold(Duration.ofMillis(
200
))
.slowCallRateThreshold(
50
.0F)
.build())
.build());
}
Now, the delayed responses are not finished with timeout, however the circuit breaker is still recording these records. When the threshold is exceeded the circuit breaker is open as shown below.

Recommend
-
153
Resilience4j - a lightweight, flexible circuit breaker Sep 13, 2017 • Philippa Main
-
23
In a previous post we talked about the implementation of the Circuit Breaker pattern . As a reminder, the Circuit Breaker is a pattern that...
-
26
内容纲要 Resilience4j是一个轻量级、易于使用的容错库,其灵感来自Netflix Hystrix,但专为Java 8和函数式编程设计。轻量级,因为库只使用Vavr,它没有任何其他外部库依赖项。相比之下,Netflix Hystrix对Archaius有一...
-
40
[译]2020年Spring状态报告 近日VMware发布了2020年Spring状态报告,该报告调查了1000多位不同行业的springboot开发者、架构师、技术经理等角色,以了...
-
14
In this series so far, we have learned about Resilience4j and its Retry, RateLimiter,
-
6
Circuit breaker with Resilience4j Reading Time: 4 minutesIn this article we will be talking about a fault tolerance librar...
-
43
Implementing Retry with Resilience4j and Spring BootIn this series so far, we have learned how to use the Resilience4j Retry,
-
12
In this series so far, we’ve learned how to use the Resilience4j Retry, RateLimiter,
-
45
Testing Spring Cloud Feign client resiliency using Resilience4J Now that we’ve checked how to test your Eureka integrated Spring Cloud Feign clients, I wanna turn over to another really interesting topic, testing resiliency....
-
11
Spring Cloud Feign traffic cut-off with Resilience4J TimeLimiter Most probably you’ve at least heard about circuit breaking if you’ve dealt with microservices. HTTP is still a common protocol to choose when setting up th...
About Joyk
Aggregate valuable and interesting links.
Joyk means Joy of geeK